HS-150IT Intrinsically safe accelerometer with temperature output, top exit, PUR cable

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), PUR cable.

  • Output AC IEPE + 10 mV/°C
  • Sensitivity 10 … 500 mV/g
  • Exit Top exit
  • IP IP68
Ordering options

Sensitivity

Mounting thread

You do not have to choose every option — we will agree the rest in the quotation.

Talk to an engineer

Technical data is taken from the manufacturer's documentation. Before ordering, please confirm the parameters against the current datasheet or with our engineer.

Key features

  • Intrinsically safe version — approvals: Europe (ATEX), USA, India (PESO), Australia (IECEx certificate)
  • Temperature output
  • For use with portable data collectors
  • Piezoelectric element in shear design

Technical specifications

Parameters as specified by the manufacturer.

Measurement
Measured quantityVibration acceleration, Temperature
Number of measuring axes1 axis
Resonant frequency (mounted)26–34 kHz
Output signal
Output typeAC (IEPE) — acceleration, Temperature 10 mV/°C
Sensitivity10 / 30 / 50 / 100 / 250 / 500 mV/g (standard: 100)
Sensitivity — notes±10%; 10mV/g, 30mV/g, 50mV/g, 100mV/g, 250mV/g, 500mV/g; Nominal 80Hz at 22°C / 72°F
Connection and mounting
Cable / connector exitTop exit
Integral cablePUR
Mounting thread1/4"-28 UNF, female (standard), 1/4"-28 UNF, male, Quick Fit, female, M6 × 1 mm, male, M8 × 1.25 mm, male, M10 × 1.5 mm, male
Operating conditions and protection
IP ratingIP68
Electromagnetic compatibility (EMC)EN 61326-1:2013
Hazardous areas and approvals
Hazardous-area versionIntrinsically safe (Ex i)
Ex marking and ambient temperatureEx ia I Ma (-55°C ≤ Ta ≤ +103°C) (mining) Ex ia IIC T4 Ga (-55°C ≤ Ta ≤ +103°C) (gas) Ex ia IIC T6 Ga (-55°C ≤ Ta ≤ +57°C) (gas) Ex ia IIIB T110°C Da (-55°C ≤ Ta ≤ +57°C) (dust) Ex ia IIIB T145°C Da (-55°C ≤ Ta ≤ +92°C) (dust) Ex ia IIIC T135°C Da (-55°C ≤ Ta ≤ +70°C) (dust)
Approvals and certificatesATEX (EU), IECEx, US approval (Class / Division), PESO (India)
Construction
Sensing elementPZT — shear
Product linePremium
Case materialStainless steel
Weight106 g (nominal, body only)
FeaturesFor data collectors
Identification
ModelHS-150IT
HS Sensors part no.HS-150IT-TOP-PUR
Manufacturer's product nameHS-150IT – Top Exit – Integral PUR Cable Intrinsically Safe Accelerometer with Temp Output

Documentation

Other HS-150IT versions

All HS-150IT variants

The same model with a different cable exit, connector or cable type.