HS-150 Industrial AC accelerometer, top exit, M12 connector
Output: AC 100 mV/g (acceleration), M12 connector.
- AC IEPE
- 100 mV/g
- Top exit
- M12
PDF datasheet
Exclusive Hansford Sensors distributor for Poland, the Czech Republic and Slovakia
PZT piezoelectric element working in shear — Premium series (HS-150, HS-170, HS-180, biaxial and triaxial sensors).
A good place to start — every model comes in several connection variants.
71 products

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), PUR cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and PT100 (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and PT100 (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC (acceleration), PUR cable in protective conduit.
PDF datasheet

Output: 2 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 2 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: 3 × AC 100 mV/g (acceleration) and 10 mV/°C (temperature), 5-core PTFE cable in protective conduit.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: 3 × AC 100 mV/g (acceleration) and 10 mV/°C (temperature), PTFE cable in protective conduit.
PDF datasheet
Filters
10 products of 71

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and PT100 (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC (acceleration), PUR cable in protective conduit.
PDF datasheet

Output: AC 100 mV/g (acceleration), 3-pin MS connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), FEP cable in protective conduit.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), PUR cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), braided cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), 3-pin MS connector.
PDF datasheet
Filters1
Clear allAC (IEPE) — voltage vibration signal for analysers and online monitoring systems. 4–20 mA — loop-powered current signal for PLC/DCS/SCADA. Line Drive — current signal for analysers that support it.
Sensitivity of an AC accelerometer. 100 mV/g is the standard in vibration diagnostics; lower sensitivities are used for high vibration levels, higher ones for very low levels.
Versions designed for hazardous areas. Certification details (category, group, temperature class, barriers) are given in the datasheet and the certificate.
In the catalogue: −55 … +150 °C. Products whose range covers the values entered will be shown.
Shear design gives a shorter settling time and greater stability; compression design is the proven general-purpose standard.