HS-420d 4–20 mA vibration sensor (velocity) with Ex d terminal head
Output: 4–20 mA (vibration velocity).
- 4–20 mA
- Ex d
PDF datasheet
Exclusive Hansford Sensors distributor for Poland, the Czech Republic and Slovakia
Intrinsically safe versions of 4–20 mA sensors for hazardous areas.
20 products

Output: 4–20 mA (vibration velocity).
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (acceleration), M12 connector.
PDF datasheet

Outputs: 4–20 mA (acceleration) and temperature signal, M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), PUR cable.
PDF datasheet

Output: 4–20 mA (vibration velocity), braided cable.
PDF datasheet

Output: 4–20 mA (vibration velocity), 2-pin MS connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), flame-retardant (FR) cable, for terminal head connection.
PDF datasheet

Output: 4–20 mA (vibration velocity), flame-retardant (FR) cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and 10 mV/°C (temperature), PUR cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), PUR cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), braided cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), 3-pin MS connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), flame-retardant (FR) cable.
PDF datasheet

Output: 4–20 mA (acceleration), PUR cable.
PDF datasheet

Output: 4–20 mA (acceleration), 2-pin MS connector.
PDF datasheet

Output: 4–20 mA (acceleration), flame-retardant (FR) cable.
PDF datasheet

Output: 4–20 mA (acceleration), braided cable.
PDF datasheet
Filters
7 products of 20

Output: 4–20 mA (vibration velocity), PUR cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and 10 mV/°C (temperature), PUR cable.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), PUR cable.
PDF datasheet

Output: 4–20 mA (acceleration), PUR cable.
PDF datasheet

Output: 4–20 mA (vibration velocity), 2-pin MS connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and AC (acceleration), 3-pin MS connector.
PDF datasheet

Output: 4–20 mA (acceleration), 2-pin MS connector.
PDF datasheet
Filters2
Clear allWhat the sensor measures: vibration acceleration (spectrum analysis, bearings), vibration velocity (condition assessment to ISO 10816/20816) or temperature.
AC (IEPE) — voltage vibration signal for analysers and online monitoring systems. 4–20 mA — loop-powered current signal for PLC/DCS/SCADA. Line Drive — current signal for analysers that support it.
Vibration velocity range corresponding to 4–20 mA, selected when ordering.
PUR — resistant to oil and abrasion. Braided — mechanical protection. FR — flame-retardant. HFFR — halogen-free (polyolefin). FEP/PTFE — high temperatures and chemicals.
Versions designed for hazardous areas. Certification details (category, group, temperature class, barriers) are given in the datasheet and the certificate.
As declared by the manufacturer in the product description. Current certificates are available in the documentation.