HS-150 Industrial AC accelerometer, top exit, M12 connector
Output: AC 100 mV/g (acceleration), M12 connector.
- AC IEPE
- 100 mV/g
- Top exit
- M12
PDF datasheet
Exclusive Hansford Sensors distributor for Poland, the Czech Republic and Slovakia
Catalogue of Hansford Sensors vibration sensors, 4–20 mA transmitters and accessories. Filter by output type, connector, IP rating, hazardous-area approval and other parameters.
419 products

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity).
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 4–20 mA (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC (vibration velocity), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and PT100 (temperature), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet
12 products of 419

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), flame-retardant (FR) cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), PUR cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), braided cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), 2-pin MS connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), flame-retardant (FR) cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), PUR cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), braided cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), 2-pin MS connector.
PDF datasheet
Filters
Filters1
Clear allSensitivity of an AC accelerometer. 100 mV/g is the standard in vibration diagnostics; lower sensitivities are used for high vibration levels, higher ones for very low levels.
Top exit — the cable leaves along the sensor axis (the most common option). Side exit — low profile: for tight spaces, guards, dust and dirt.
PUR — resistant to oil and abrasion. Braided — mechanical protection. FR — flame-retardant. HFFR — halogen-free (polyolefin). FEP/PTFE — high temperatures and chemicals.
In the catalogue: −55 … +150 °C. Products whose range covers the values entered will be shown.
Shear design gives a shorter settling time and greater stability; compression design is the proven general-purpose standard.