
HS-150 Industrial AC accelerometer, top exit, M12 connector
Output: AC 100 mV/g (acceleration), M12 connector.
- AC IEPE
- 100 mV/g
- Top exit
- M12
PDF datasheet
Exclusive Hansford Sensors distributor for Poland, the Czech Republic and Slovakia
Catalogue of Hansford Sensors vibration sensors, 4–20 mA transmitters and accessories. Filter by output type, connector, IP rating, hazardous-area approval and other parameters.
419 products

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity).
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 4–20 mA (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: 4–20 mA (vibration velocity) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 4–20 mA (vibration velocity), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC (vibration velocity), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration).
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and PT100 (temperature), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet
Filters
419 products

Stainless steel enclosure with protective roof.
PDF datasheet

Stainless steel enclosure.
PDF datasheet

Polycarbonate enclosure.
PDF datasheet

Stainless steel enclosure with protective roof and outputs for online expansion.
PDF datasheet

Stainless steel enclosure with outputs for online expansion.
PDF datasheet

Stainless steel enclosure with hinged connection board.
PDF datasheet

Output: temperature signal.
PDF datasheet

Stainless steel enclosure with protective roof.
PDF datasheet

Stainless steel enclosure.
PDF datasheet

Stainless steel enclosure.
PDF datasheet

Painted mild steel enclosure.
PDF datasheet
Filters
What the sensor measures: vibration acceleration (spectrum analysis, bearings), vibration velocity (condition assessment to ISO 10816/20816) or temperature.
AC (IEPE) — voltage vibration signal for analysers and online monitoring systems. 4–20 mA — loop-powered current signal for PLC/DCS/SCADA. Line Drive — current signal for analysers that support it.
Sensitivity of an AC accelerometer. 100 mV/g is the standard in vibration diagnostics; lower sensitivities are used for high vibration levels, higher ones for very low levels.
Top exit — the cable leaves along the sensor axis (the most common option). Side exit — low profile: for tight spaces, guards, dust and dirt.
Versions designed for hazardous areas. Certification details (category, group, temperature class, barriers) are given in the datasheet and the certificate.
As declared by the manufacturer in the product description. Current certificates are available in the documentation.
PUR — resistant to oil and abrasion. Braided — mechanical protection. FR — flame-retardant. HFFR — halogen-free (polyolefin). FEP/PTFE — high temperatures and chemicals.
The cable runs in a protective conduit (e.g. stainless steel) — additional mechanical protection.
Yes28In the catalogue: −55 … +150 °C. Products whose range covers the values entered will be shown.
Vibration velocity range corresponding to 4–20 mA, selected when ordering.
Shear design gives a shorter settling time and greater stability; compression design is the proven general-purpose standard.