
HS-100I Intrinsically safe accelerometer, top exit, M12 connector
Output: AC 100 mV/g (acceleration), M12 connector.
- AC IEPE
- 10 … 100 mV/g
- Top exit
- IP67
PDF datasheet
Exclusive Hansford Sensors distributor for Poland, the Czech Republic and Slovakia
Intrinsically safe versions for gas and dust hazardous areas.
52 products

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), low-noise cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), low-noise cable.
PDF datasheet

Output: Line Drive (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Output: AC (acceleration), PUR cable in protective conduit.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: 3 × AC 100 mV/g (acceleration), M12 connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), PUR cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), braided cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), 2-pin MS connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), PUR cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), braided cable.
PDF datasheet

Output: AC 100 mV/g (acceleration), 2-pin MS connector.
PDF datasheet

Output: AC 100 mV/g (acceleration), 3-pin MS connector.
PDF datasheet

Output: Line Drive (acceleration), 2-pin MS connector.
PDF datasheet
Filters
8 products of 52

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), M12 connector.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), braided cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), PUR cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), 3-pin MS connector.
PDF datasheet

Outputs: AC (acceleration) and temperature signal, braided cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), PUR cable.
PDF datasheet

Outputs: AC 100 mV/g (acceleration) and 10 mV/°C (temperature), 3-pin MS connector.
PDF datasheet
Filters1
Clear allAC (IEPE) — voltage vibration signal for analysers and online monitoring systems. 4–20 mA — loop-powered current signal for PLC/DCS/SCADA. Line Drive — current signal for analysers that support it.
Top exit — the cable leaves along the sensor axis (the most common option). Side exit — low profile: for tight spaces, guards, dust and dirt.
Versions designed for hazardous areas. Certification details (category, group, temperature class, barriers) are given in the datasheet and the certificate.
What the sensor measures: vibration acceleration (spectrum analysis, bearings), vibration velocity (condition assessment to ISO 10816/20816) or temperature.